Technology
Standards
IEEE802.3 10BASE-T, IEEE802.3u 100BASE-TX/FX, IEEE802.3x
Forward and Filtering Rate
14,880pps for 10Mbps
148,810pps for 100Mbps
Packet Buffer Memory
448K bits
Processing Type
Store-and-Forward
Half-duplex back-pressure and IEEE802.3x full-duplex flow control
Address Table Size
2048 MAC addresses
Power
Input
Input Voltage: 12VDC (DC Jack); 12 to 48VDC (Terminal Block)
Power Consumption
6W Max. 12VDC @ 0.5A, 24VDC @ 0.25A, 48VDC @0.125A
Reverse Polarity Protection
Present
Mechanical
Casing
Aluminum case
Dimensions
60mm (W) x 125mm (D) x 145mm (H)
(2.36" (W) x 4.92" (D) x 5.7" (H))
Weight
1Kg (2.2lbs.)
Installation
DIN-Rail, Panel Mounting
Interface
LED Indicators
Per Unit: Power Status: Power 1, 2, 3 (Green)
Per Port: 10/100TX, 100FX: Link/Activity (Green)Fault
Alarm Contact
One relay output with current 1A @ 24VDC
Environment
Operating Temperature
-40°C to 75°C (-40°F to 167°F)
Tested @ -40°C to 85°C (-40°F to 185°F)
Storage Temperature
-40°C to 85°C (-40°F to 185°F)
Ambient Relative Humidity
5% to 95% (non-condensing)
Regulatory Approvals
ISO
Manufactured in an ISO9001 facility
Safety
UL508 (Pending)
EMI
FCC Part 15, Class A
EN61000-6-4
- EN55022
- EN61000-3-2
- EN61000-3-3
EMS
EN61000-6-2
- EN61000-4-2 (ESD Standards)
Contact: + / - 8KV; Criteria B
Air: + / - 15KV; Criteria B
- EN61000-4-3 (Radiated FRI Standards)
35V/m, 80 to 3G; 80% AM Criteria A
- EN61000-4-4 (Burst Standards)
Signal Ports: + / - 4KV
D.C. Power Ports: + / - 4KV; Criteria B
A.C. Power Ports: + / - 4KV; Criteria B
- EN61000-4-5 (Surge Standards)
Signal Ports: + / - 2KV; Line-to-Line; Criteria B
D.C. Power Ports: + / - 4KV; Line-to-earth; Criteria B
- EN61000-4-6 (Induced RFI Standards)
Signal Ports: 10V @ 0.15 - 80MHz; Criteria A
D.C. Power Ports: 10V @ 0.15 - 80MHz; Criteria A
A.C. Power Ports: 10V @ 0.15 - 80MHz; Criteria A
Earth Ground Ports: 10V @ 0.15 - 80MHz; Criteria A
- EN61000-4-8 (Magnetic Field Standards)
1000A/m @ 50, 60Hz; Criteria A
- IEC 61000-4-10(Oscillatory wave magnetic field test)
100kHz and 1MHz: 30A/m
- IEC 61000-4-16 (Power frequency immunity test) 50Hz: 300V
- IEC 61000-4-18 (oscillatory wave immunity test):
100 kHz, 2.5kV CM and 2.5kV DM
1MHz , 2.5kV CM and 2.5kV DM
- IEEE1613:
power frequency withstand voltage: 2KV, Insulation
resistance >550 MOhm
RJ45 Port 500V, Insulation resistance >550 MOhm
Impulse voltage: 5Kv, Insulation resistance >550 MOhm
IEC 60870-2-1: AC/DC power supply voltage varia tions
Environmental Test Compliance
IEC60068-2-6 (Vibration Resistance)
5G @ 150Hz; Criterion 3 (Operation/Storage/Transport)
IEC60068-2-27 (Shock)
25G @ 11ms (Half-Sine Shock Pulse; Operation)
50G @ 11ms (Half-Sine Shock Pulse; Storage/Transport)
IEC60068-2-32 (Free Fall)
1M (3.281ft.)