Technology
Standards:
IEEE802.3 10BASE-T, IEEE802.3u 100BASE-TX/100BASE-FX,
IEEE802.3ab 1000BASE-T, IEEE802.3z 1000BASE-SX/1000BASE-LX,
IEEE802.3x, IEEE802.1Q, IEEE802.1p, IEEE802.1w
Protocols:
IGMP, GVRP, SNMP V1/V2c, RMON, TFTP
Forward and Filtering Rate:
14,880pps for 10Mbps
148,810pps for 100Mbps
1,488,100pps for 1000Mbps
Packet Buffer Memory:
16M bits
Processing Type:
Store-and-Forward
Half-duplex back-pressure and IEEE802.3x full-duplex flow control
Address Table Size:
12288 MAC addresses
Latency:
Less than 151.5μs
Power
Input:
AC : 100 ~ 240VAC, 50 ~ 60Hz Internal Universal PSU
DC : + / -48VDC
Power Consumption:
34.8W Max.
Overload Current Protection:
Present
Mechanical
Casing:
Metal case
IP20
Dimensions:
Single Power: 443.6mm (W) x 284.1mm (D) x 44mm (H)
(17.47" (W) x 11.19" (D) x 1.73" (H))
Redundant Power: 443.6mm (W) x 403mm (D) x 44mm (H)
(17.47" (W) x 15.87" (D) x 1.73" (H))
Standard 19" rack-mount size, one-unit-height
Weight:
3.4Kg (7.5lbs.)
Installation:
Rack Mounting
Interface
Ethernet Port:
10/100BASE-TX: 24, 16, 8, 6 or 0 ports
100BASE-FX: 0, 8, 16, 18 or 24 ports
Gigabit: 0, 1 or 2 ports
Console Port:
Port: One DB9 RS-232 port
LED Indicators:
Per Unit: Power Status (Power)
Per Port: 10/100TX, 100FX: Link/Activity, Full-duplex/Collision
10/100/1000TX, 1000SX/LX: Link, Activity
Environment
Operating Temperature:
-40°C to 75°C (-40°F to 167°F)
Tested @ -40°C to 85°C (-40°F to 185°F)
Storage Temperature:
-40°C to 85°C (-40°F to 185°F)
Ambient Relative Humidity:
5% to 95% (non-condensing)
Regulatory Approvals
ISO:
Manufactured in an ISO9001 facility
Safety:
UL60950-1, EN60950-1, IEC60950-1
EMI:
FCC Part 15, Class A
EN61000-6-4
EN55022
EN61000-3-2
EN61000-3-3
EMS:
EN61000-6-2
EN61000-4-2 (ESD Standards)
Contact: + / - 4KV; Criteria B
Air: + / - 8KV; Criteria B
EN61000-4-3 (Radiated RFI Standards)
10V/m, 80 to 1000MHz; 80% AM Criteria A
EN61000-4-4 (Burst Standards)
Signal Ports: + / - 4KV; Criteria B
D.C. Power Ports: + / - 4KV; Criteria B
A.C. Power Ports: + / - 4KV; Criteria B
EN61000-4-5 (Surge Standards)
Signal Ports: + / - 1KV; Line-to-Line; Criteria B
D.C. Power Ports: + / - 0.5KV; Line-to-earth; Criteria B
A.C. Power Ports: + / - 2KV; Line-to-earth; Criteria B
EN61000-4-6 (Induced RFI Standards)
Signal Ports: 10Vrms @ 0.15~80MHz; 80% AM Criteria A
D.C. Power Ports: 10Vrms @ 0.15~80MHz; 80% AM Criteria A
A.C. Power Ports: 10Vrms @ 0.15~80MHz; 80% AM Criteria A
EN61000-4-8 (Magnetic Field Standards)
30A/m @ 50, 60Hz; Criteria A
EN61000-4-11 (Voltage Dip Standards)
A.C. Power Ports: 30% Reduction for 0.5 period; Criteria B
Environmental Test Compliance:
IEC60068-2-6 Fc (Vibration Resistance)
5g @ 10~150Hz, Amplitude 0.35mm (Operation/Storage/Transport)
IEC60068-2-27 Ea (Shock)
25g @ 11ms (Half-Sine Shock Pulse; Operation)
50g @ 11ms (Half-Sine Shock Pulse; Storage/Transport)
IEC60068-2-32 Ed (Free Fall)
1M (3.281ft.)